![]() ![]() This may not be the best option unless you are renovating. This is ideal and recommended during renovation work, but is expensive and can necessitate opening up wall or ceiling finishes. The most obvious and most expensive repair is to re-wire or run new three-wire cables in the house.I will review 4 of the most common repairs. In houses wired with a 2-wire system, typically pre-1962, you have many different options for repair.In this case, you need to diagnose this circuit and find where the circuit has become disconnected. Post-1962 houses are likely to have a three wire system and the conductor has simply become disabled. The first step is to determine if there is an equipment grounding conductor present on the circuit.Here are some options for correcting this relatively common problem. This exemplifies why it is so important to take even little wiring problem seriously. This is a common electrical safety phenomenon: one thing wrong is a little unsafe but multiple defects can quickly escalate into a serious safety hazard. You would not even need to switch the appliance on to get electrocuted. If this same circuit also has reversed polarity, where the hot and the neutral are backward, also a common defect, you could now energize the appliance jacket just by plugging it in. Your chances of electrocution have gone up. but there is no conductor present to discharge the fault. If that jacket becomes energized the design of the appliance is to discharge that fault onto the equipment grounding conductor…. Is an open ground unsafe?Ī residential electrical system is less safe when there is no equipment ground and this condition is exacerbated when you have an open ground. To understand why, visualize plugging in an appliance that has a metal jacket that could be energized – maybe an older power tool or vacuum. You can also find open grounds in post-1962 houses where the equipment grounding conductor has been disabled for one reason or another. When old two-prong receptacles are replaced with modern three-prong receptacles and a grounding conductor is not added, you create an open ground. This is unsafe because an appliance that is designed to use an equipment ground to discharge an unsafe fault condition will not have a conductor to discharge that fault. Open grounds are common in houses built prior to the adoption of the 1962 electrical code. What is an open ground?Īn open ground is when you have a three-prong receptacle that is not connected to an equipment grounding conductor. Most of these houses were “two-prong,” or “two-wire,” system. Houses built prior to the adoption of the 1962 electrical code rarely had equipment grounding conductors. Residential wiring systems will function properly without an equipment ground but these conductors make our electrical systems safer by providing a low resistance path for fault current to return to the electric panel and trip the breaker to disable a dangerous fault condition. ![]() The equipment ground in residential wiring is often thought of as the “third prong” in an electrical receptacle and the third, bare conductor in an electrical circuit. The circle shows the third prong or equipment grounding slot in a three-prong receptacle.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |